Page 20 - JOOSHIN CORPORATION
P. 20

JooShin
                                     VW Type Load Cell                                             Corporation


























  Dimension
       Ityem No.           SJ-50         SJ-100        SJ-120        SJ-150        SJ-200        SJ-300
    Capacity (ton•f)         50            100           120           150           200           300
  Cross section (mm²)       2,356         6,518         7,193         8,432         9,632         7,193
           ID (mm)           35            75            85            100           125           85
           OD (mm)           65            118           128           144           167           128
   Dime     L (mm)           78            148           160           175           197           160
   nsion
            H (mm)         80(112)      102(132)      102(132)       102(132)      102(132)     102(132)
            W (kg)         1.4(2.1)      5.3(7.3)      5.7(8.1)      6.7(9.9)      7.7(11.4)     5.7(8.1)



  Reference
                  2
  Linear Value  (KHz )
    - Application: It can be used for VW load cell and VW pressure sensors. It is also mainly used when the frequency value is
      decreased according to the increase in the engineering unit which is the reference standard for calibration.
              2
           3
    - Unit: 10 Hz
   - Unit Conversion
                         3
                                    2
                                 3
    a) Hz is converted into 10 Hz2  : 10 Hz  = Hz × Hz / 1000
                                           2
                                        3
        3
           2
    b) 10 Hz  is converted into Hz  : Hz = √(10 Hz  × 1000)























                                               www.jooshin.kr                                     20